173 research outputs found

    Age-related changes in P wave morphology in healthy subjects

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We have previously documented significant differences in orthogonal P wave morphology between patients with and without paroxysmal atrial fibrillation (PAF). However, there exists little data concerning normal P wave morphology. This study was aimed at exploring orthogonal P wave morphology and its variations in healthy subjects.</p> <p>Methods</p> <p>120 healthy volunteers were included, evenly distributed in decades from 20–80 years of age; 60 men (age 50+/-17) and 60 women (50+/-16). Six-minute long 12-lead ECG registrations were acquired and transformed into orthogonal leads. Using a previously described P wave triggered P wave signal averaging method we were able to compare similarities and differences in P wave morphologies.</p> <p>Results</p> <p>Orthogonal P wave morphology in healthy individuals was predominately positive in Leads X and Y. In Lead Z, one third had negative morphology and two-thirds a biphasic one with a transition from negative to positive. The latter P wave morphology type was significantly more common after the age of 50 (P < 0.01). P wave duration (PWD) increased with age being slightly longer in subjects older than 50 (121+/-13 ms vs. 128+/-12 ms, P < 0.005). Minimal intraindividual variation of P wave morphology was observed.</p> <p>Conclusion</p> <p>Changes of signal averaged orthogonal P wave morphology (biphasic signal in Lead Z), earlier reported in PAF patients, are common in healthy subjects and appear predominantly after the age of 50. Subtle age-related prolongation of PWD is unlikely to be sufficient as a sole explanation of this finding that is thought to represent interatrial conduction disturbances. To serve as future reference, P wave morphology parameters of the healthy subjects are provided.</p

    Critical appraisal of technologies to assess electrical activity during atrial fibrillation: a position paper from the European Heart Rhythm Association and European Society of Cardiology Working Group on eCardiology in collaboration with the Heart Rhythm Society, Asia Pacific Heart Rhythm Society, Latin American Heart Rhythm Society and Computing in Cardiology

    Get PDF
    We aim to provide a critical appraisal of basic concepts underlying signal recording and processing technologies applied for (i) atrial fibrillation (AF) mapping to unravel AF mechanisms and/or identifying target sites for AF therapy and (ii) AF detection, to optimize usage of technologies, stimulate research aimed at closing knowledge gaps, and developing ideal AF recording and processing technologies. Recording and processing techniques for assessment of electrical activity during AF essential for diagnosis and guiding ablative therapy including body surface electrocardiograms (ECG) and endo- or epicardial electrograms (EGM) are evaluated. Discussion of (i) differences in uni-, bi-, and multi-polar (omnipolar/Laplacian) recording modes, (ii) impact of recording technologies on EGM morphology, (iii) global or local mapping using various types of EGM involving signal processing techniques including isochronal-, voltage- fractionation-, dipole density-, and rotor mapping, enabling derivation of parameters like atrial rate, entropy, conduction velocity/direction, (iv) value of epicardial and optical mapping, (v) AF detection by cardiac implantable electronic devices containing various detection algorithms applicable to stored EGMs, (vi) contribution of machine learning (ML) to further improvement of signals processing technologies. Recording and processing of EGM (or ECG) are the cornerstones of (body surface) mapping of AF. Currently available AF recording and processing technologies are mainly restricted to specific applications or have technological limitations. Improvements in AF mapping by obtaining highest fidelity source signals (e.g. catheter–electrode combinations) for signal processing (e.g. filtering, digitization, and noise elimination) is of utmost importance. Novel acquisition instruments (multi-polar catheters combined with improved physical modelling and ML techniques) will enable enhanced and automated interpretation of EGM recordings in the near future

    The association of spatial T wave axis deviation with incident coronary events. The ARIC cohort

    Get PDF
    BACKGROUND: Although current evidence suggests that the spatial T wave axis captures important information about ventricular repolarization abnormalities, there are only a few and discordant epidemiologic studies addressing the ability of the spatial T wave axis to predict coronary heart disease (CHD) occurrence. METHODS: This prospective study analyzed data from 12,256 middle-aged African American and white men and women, from the Atherosclerosis Risk in Communities Study (ARIC). Following a standardized protocol, resting standard 12-lead, 10-second electrocardiograms were digitized and analyzed with the Marquette GE program. The median follow-up time was 12.1 years; incident coronary heart disease comprised fatal and non-fatal CHD events. RESULTS: The incidence rate of CHD was 4.26, 4.18, 4.28 and 5.62 per 1000 person-years respectively, across the spatial T wave axis quartiles. Among women for every 10 degrees increase in the spatial T wave axis deviation, there was an estimated increase in the risk of CHD of 1.16 (95% CI 1.04–1.28). After adjustment for age, height, weight, smoking, hypertension, diabetes, QRS axis and minor T wave abnormalities, this hazard rate ratio for women fell to 1.03 (0.92–1.14). The corresponding crude and adjusted hazard ratios for men were 1.05 (95% CI 0.96–1.15) and 0.95 (0.86–1.04) respectively. CONCLUSIONS: In conclusion, this prospective, population-based, bi-ethnic study of men and women free of coronary heart disease at baseline shows that spatial T wave axis deviation is not associated with incident coronary events during long-term follow up. It is doubtful that spatial T wave axis deviation would add benefit in the prediction of CHD events above and beyond the current traditional risk factors

    Time Distribution of the Onset of Chest Pain in Subjects with Acute ST-Elevation Myocardial Infarction: An Eight-Year, Single-Center Study in China

    Get PDF
    Objective: The objective of this study was to explore the time distribution patterns of the onset of chest pain in subjects with acute ST-elevation myocardial infarction in a Chinese population. Methods: A total of 1467 patients with acute ST-elevation myocardial infarction were enrolled from 2003 to 2010. The hourly, daily, monthly, seasonal and day-of-week fluctuations in the prevalence of acute ST-elevation myocardial infarction were analyzed. Results: A peak was found between the morning hours of 07:31 and 08:30. A second peak was observed between 14:31 and 15:30, and a third peak was found between 23:31 and 00:30 (p,0.001). The monthly maximum was recorded in November and the minimum was in April (p,0.001). The number of daily cases was greatest in autumn and lowest in the spring (p = 0.001). Day-of-the-week variations of ST-elevation acute myocardial infarction were not found, except in patients more than 75-years-old. Conclusions: Periodic variations in the frequency of ST-elevation acute myocardial infarction in Chinese patients showed significant differences with regard to diurnal, monthly and seasonal patterns. The exact mechanisms underlying thes

    Reverse left ventricular remodeling is more likely in non ischemic cardiomyopathy patients upgraded to biventricular stimulation after chronic right ventricular pacing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Chronic right ventricular (RV) apical pacing may lead to left ventricular (LV) dyssynchrony and LV dysfunction. In heart failure due to RV pacing, upgrading to biventricular stimulation (CRT) can improve NYHA Class and LV function. A proportion of patients do not respond to upgrading. Aim was to assess whether etiology of LV dysfunction accounts for responses to CRT in RV-paced patients.</p> <p>Methods</p> <p>Sixty-two patients treated by CRT, under RV pacing from 50.2 Β± 5.4 months, were studied. Cause of LV dysfunction was non-ischemic (NIC) in 28 and ischemic cardiomyopathy (IC) in 34 patients. Clinical and conventional echocardiographic parameters were available within 1 month before RV pacing, within 1 month before CRT and at 12 Β± 2 months of follow-up (FU).</p> <p>Results</p> <p>Decreased LVEF (from 37.0 Β± 8.8 to 25.6 Β± 6.1%, p <0.001), increased LV end-systolic dimensions (LVESD) (from 48.1 Β± 8.6 to 55.2 Β± 7.9 mm, p <0.001) and worsened NYHA Class (from 1.9 Β± 1.1 to 3.2 Β± .6, p < 0.005) were found before CRT, compared to pre RV-pacing. After CRT, 44/62 patients showed a β‰₯ 1 NYHA Class improvement; >10% decrease in LVESD was observed in 24 patients: 5 with IC, 19 with NIC (p < .0.001). The association between cause of LV dysfunction with >10% decrease in LVESD remained highly significant (p < 0.001) adjusting for pre-CRT QRS duration, NYHA Class, LVEF, LVESD, treatment or RV pacing duration.</p> <p>Conclusions</p> <p>CRT improves functional class even after long-lasting pacing. Reverse remodeling is evident in a small population, more likely with NIC.</p

    Revisiting QRS detection methodologies for portable, wearable, battery-operated, and wireless ECG systems

    Get PDF
    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices.Mohamed Elgendi, BjΓΆrn Eskofier, Socrates Dokos, Derek Abbot

    Coffee, Alcohol, Smoking, Physical Activity and QT Interval Duration: Results from the Third National Health and Nutrition Examination Survey

    Get PDF
    Abnormalities in the electrocardiographic QT interval duration have been associated with an increased risk of ventricular arrhythmias and sudden cardiac death. However, there is substantial uncertainty about the effect of modifiable factors such as coffee intake, cigarette smoking, alcohol consumption, and physical activity on QT interval duration.We studied 7795 men and women from the Third National Health and Nutrition Survey (NHANES III, 1988-1994). Baseline QT interval was measured from the standard 12-lead electrocardiogram. Coffee and tea intake, alcohol consumption, leisure-time physical activities over the past month, and lifetime smoking habits were determined using validated questionnaires during the home interview.In the fully adjusted model, the average differences in QT interval comparing participants drinking β‰₯6 cups/day to those who did not drink any were -1.2 ms (95% CI -4.4 to 2.0) for coffee, and -2.0 ms (-11.2 to 7.3) for tea, respectively. The average differences in QT interval duration comparing current to never smokers was 1.2 ms (-0.6 to 2.9) while the average difference in QT interval duration comparing participants drinking β‰₯7 drinks/week to non-drinkers was 1.8 ms (-0.5 to 4.0). The age, race/ethnicity, and RR-interval adjusted differences in average QT interval duration comparing men with binge drinking episodes to non-drinkers or drinkers without binge drinking were 2.8 ms (0.4 to 5.3) and 4.0 ms (1.6 to 6.4), respectively. The corresponding differences in women were 1.1 (-2.9 to 5.2) and 1.7 ms (-2.3 to 5.7). Finally, the average differences in QT interval comparing the highest vs. the lowest categories of total physical activity was -0.8 ms (-3.0 to 1.4).Binge drinking was associated with longer QT interval in men but not in women. QT interval duration was not associated with other modifiable factors including coffee and tea intake, smoking, and physical activity
    • …
    corecore